Search:

CONTACTOR STARTERS RS 1230/2S

APPLICATION
The contactor starters are designed for controlling and powering electrical motors of mining drive systems from three-phase supply networks with the transformer’s insulated neutral point on the secondary side. The contactor starters meet the requirements of the European Directive 2014/34/UE (ATEX) for equipment In group I, category M2, and can be used in methane and coal dust explosion hazardous areas of underground mines.

 

 

 

 

 

 

 

Technical data

TypeRS 1230/2S
Nominal voltage 500 V or 1000 V 50 Hz
Nominal DC 230 A
Total input current ≤ 300 A (load capacity grip of loop-through I = 250 A - Iload)
Outside auxiliary voltages with earth
leakage control
24 V, 42 V, 50 Hz
Main channel BZU adjustment resistance 50 kΩ
Dimensions with inlets
(w x h x d)
950 x 785 x 540 mm
Protection degree of enclosure IP 54
Marking of the appliance CE1453 Ex I M2 Exd [ia Ma] I Mb
Certificate number KDB 11ATEX056X