TRANSFORMERS UNITS ZT-110/5/2S, ZT-110/52/2S

APPLICATION
The transformer units are designed for supplying lighting circuits with decreased voltage of 230 V or 500 V and control of low power motors. The transformer units meet the requirements of the European Directive 2014/34/UE (ATEX) for equipment in group I, category M2, and can be used in methane and coal dust explosion hazardous areas of underground mines.

 

 

 

 

 

 

Technical data

TypeZT-110/5/2S       ZT-110/52/2S
Three-phase transformer power 10 kVA + 0,2 kVA
Primary voltage 1000 V, 50 Hz
Secondary voltage I 500 V, 50 Hz
Secondary voltage II - 230 V, 50 Hz
Rated power for 500 V: Duty cycles S1 10 kVA
Rated power for 500 V: Duty cycles S3 16 kVA
Rated secondary current I 11,6 A
Rated secondary current I – duty cycles S3 18,5 A
Rated power for 230 V - 3,5 kVA
Rated secondary current II - 8,8 A
Overcurrent protection range (0,5-20) A
Adjusted resistance: Central leakage protection - 500 V 15 kΩ
Adjusted resistance: Central leakage protection - 230 V - 7 kΩ
Adjusted resistance: Interlocking protection - 500 V, 230 V 50 kΩ
Dimmensions with inlets (w x h x d) 1155 x 935 x 730 mm
Protection degree of enclosure IP54
Marking of the appliance CE 1453 Ex I M2 Ex d [ia Ma] I Mb
Certificate number KOMAG 15ATEX0354X