Search:

TRANSFORMERS UNITS ZT-150, ZT-150S

APPLICATION
The transformer units are designed for supplying lighting circuits with decreased voltage of 133 V or 230 V and control of low power motors. The transformer units meet the requirements of the European Directive 2014/34/UE (ATEX) for equipment in group I, category M2, and can be used in methane and coal dust explosion hazardous areas of underground mines.

 

 

 

 

 

 

Technical data

TypeZT-150, ZT-150S
Three-phase transformer power 5 kVA + 0,2 kVA
Primary voltage 500 V or 1000 V 50 Hz (switchable)
Secondary voltage 133 V or 230 V (switchable)
Rated secondary current 133/230 V 20 A/12,5 A
Auxiliary voltage with earth leakage control 24 V, 42 V
Overcurrent protection range 0,5-20 A
Adjusted resistance Central leakage protection -133 V i 230 V 7 kΩ
Interlocking protection - 133V i 230 V 15 kΩ
Dimmensions with inlets (w x h x d) 950 x 785 x 540 mm
Protection degree of enclosure IP 54
Marking of the appliance CE 1453 IM2 Ex d [ia Ma] I Mb
Certificate number KDB 12ATEX0150X