High quality Polish hybrid ultrasonic heat/cooling meter

INVONIC H is a modern and precise ultrasonic heat meter with ultrasonic flow sensor, that guarantees high measurement precision with a long term operating life regardless of  its  mounting position. The ultrasonic heat meter has a modular design, making possible to extend its functionality at any time by installing a communication module, changing the power supply option or replacing different temperature sensors. A robust brass body of flow sensor is available in a version with a threaded or flanged connection and may be used in the pressure scopes PN16 or PN25. The heat meter indications are entirely non-sensitive to external magnetic fields.

 

Ultrasonic heat meter usage

INVONIC H is an ultrasonic heat meter used for the measurement of energy consumption in heating or cooling systems (optional) intended for residential, office and industrial facilities.  Ultrasonic  flow  sensor,  with  brass housing, is key part of device that ensures high precision, dynamics and  measurement  stability  of  meter  regardless  of  its  mounting position  (horizontal/vertical) and ensures non-sensitivity of device to magnetic field. The communication module provide remote readout of information from the meter both by wire (M-Bus, Modbus RTU, BACnet MS/TP, pulse outputs) and wirelessly (Wireless M-Bus 868 MHz T1 OMS), allowing  cooperation  of INVONIC  H  with  different  data  reading  systems  and  building automation.

 

 

Ultrasonic heat meter features

Cechy ciepłomerza ultradźwiękowego INVONIC H

 

Measurement precision

  • High stability of metrological parameters has been achieved for the entire operating life, thanks to signal strength compensation.
  • Wide measurement range in any working position (H, V, H/V)
  • The starting flow of flow sensor can be as low as 3 l/h
  • Small pressure drops from 1 to 20 mbar for qp flow  (pressure drop amount depending on the length of installation and the value of the nominal flow)
     
     

Advantages

  • capable to work with systems containing water or glycol-water solutions (ethylene / propylene glycol)
  • easy to read 8 digit display, with symbols indicating operation state of meter, operated by a single button
  • rotatable by 180° calculator with wall-mount possibility (standard length of connecting cable 1,2 m)
  • power supply from 230 V AC, 24 V AC/DC or battery (battery lifetime up to 11 years)
  • built-in data logger capable of storing data from last 36 months for period of 15 years without power supply
  • integrated pulse outputs for energy and volume or two pulse inputs for water meters
  • possibility to mount communication modules without compromising manufacturer protecting seals

 

Basic technical data

TypeDynamic rangeqp
[m3/h]
DN
[mm]
Length
[mm]
Weight
[kg]
Hybrid ultrasonic heat/cooling meter INVONIC H
INVONIC H 0,6 1:100 0,6 15 110 0,8
INVONIC H 0,6 0,6 20 190 1,1
INVONIC H 0,6 0,6 20 190 2,9
INVONIC H 1,0 1:100 1,0 15 110 0,8
INVONIC H 1,0 1,0 20 190 1,1
INVONIC H 1,0 1,0 20 190 2,9
INVONIC H 1,5 1:100 1:250 1,5 15 110 0,8
INVONIC H 1,5 1,5 20 190 1,1
INVONIC H 1,5 1,5 20 190 2,9
INVONIC H 1,5 1:100 1,5 20 130 0,9
INVONIC H 2,5 1:100 1:250 2,5 20 130/190 0,9/1,1
INVONIC H 2,5 2,5 20 190 2,9
INVONIC H 3,5 1:100 3,5 25 260 3,6
INVONIC H 3,5 3,5 25 260 6,1
INVONIC H 6,0

1:100 1:250

6,0 25 260 3,6
INVONIC H 6,0 6,0 25 260 6,1
INVONIC H 10,0 1:100 1:250 10,0 40 300 7,2
INVONIC H 10,0 10,0 40 300 8,4
INVONIC H 15,0 1:100 1:250 15,0 50 270 8,5
INVONIC H 25,0 1:100 1:250 25,0 65 300 13,0
INVONIC H 40,0 1:100 1:250 40,0 80 300 15,0
INVONIC H 60,0 1:100 1:250 60,0 100 360 18,0

 - temperature scope of the flowing medium: 5÷130°C. Minimum temperature only regards type approval (the meter measurement accuracy starts at 0.1°C)
- nominal pressure: PN16/PN25*
- flow sensor protection class: IP65/IP67*; calculator protection class: IP65
- energy units: GJ (kWh, MWh, Gcal)*

*) Optional