microBEL SRS

Controls for MV switchgear

  • Operations on MV overhead switchgear/disconnectors

  • Earth fault and phase-to-phase fault detection functions

  • Remote diagnostics of an uninterruptible power supply

Ask about this product

Na każdą wiadomość staramy się odpowiadać maksymalnie w 24 godziny (dni robocze).

Discover the capabilities of microBEL SRS

microBEL SRS controllers are designed to operate overhead MV switchgear/disconnecting points equipped with measuring systems capable of measuring phase currents and voltages. Based on these measurements, the controller performs earth fault and phase-to-phase fault detection functions in networks with any type of neutral point configuration.

microBEL SRS devices integrate the functions of a fault indicator and a telemechanics unit. The software configuration of the controllers includes a range of protection criteria – from overcurrent and earth fault protection to admittance and directional earth fault protection, etc. allowing the selection of the appropriate criterion to ensure effective and reliable fault detection in MV networks – which is an essential element for the correct operation of FDIR (Fault Detection, Isolation and Restoration) automation systems.

In addition to controlling switch disconnectors, microBEL SRS controllers provide remote diagnostics for uninterruptible power supplies, support local change-over switches (e.g. control mode, setting banks) and signals (e.g. open-door signal). microBEL SRS controllers are equipped with several communication ports, enabling them to communicate simultaneously with the monitoring system using, among others, TETRA, Trunking, NETMAN, GSM/3G/LTE radio networks, as well as 100Base-Tx Ethernet (e.g. for communication with an AMI router).

Controllers from the microBEL family can be equipped with a range of mechanisms ensuring full IT security during the exchange and transmission of information, including authentication in accordance with IEC-62351 and the 802.1x standard, IPSec tunnel establishment, firewall functionality, etc.

Operation of overhead MV switchgear and disconnectors

Measurement of phase currents and voltages

Detection of earth faults and phase-to-phase faults in MV networks

Integration of the short-circuit indicator and the telemechanics unit

Configurable protection criteria (overcurrent, earth fault, admittance, directional)

Support for FDIR (Fault Detection, Isolation and Restoration) automation systems

Remote diagnostics of an uninterruptible power supply

Support for local change-over switches I-0-II and station signals (e.g. doors, control mode)

Multi-channel communication with the surveillance system (TETRA, Trunking, NETMAN, GSM/3G/LTE, Ethernet)