MWN130-NC (DN40–300)

Screw transducers (Woltman) with a horizontal rotor axis

  • Polish mechanical heat meter flow transducers MWN130-NC

  • Immunity to external magnetic fields, in accordance with EN 14154-3 and EN-ISO 4064-2

  • Accuracy of readings – compliance with MID metrological requirements

Ask about this product

Na każdą wiadomość staramy się odpowiadać maksymalnie w 24 godziny (dni robocze).

Find out what the MWN130-NC flow transducer (DN40–300) has to offer

The MWN130-NC is a Polish-made mechanical Woltman-type flow meter with a horizontal rotor axis, designed for cooperation with heat meter display units. The device is capable of measuring the volume of water at temperatures ranging from 0.1°C to 130°C in closed systems, at a maximum operating pressure of 16 bar (PN16). The flow meter is designed for installation in horizontal pipelines with the counter facing upwards (H), as well as in vertical and inclined pipelines with the counter facing sideways or in CT/VT positions. It is equipped as standard with a painted body offering excellent corrosion resistance and mechanical properties, and a rotor mounted on bearings at both ends. The device’s design ensures resistance to external magnetic fields and meets MID metrological requirements. The flow transducer is used in district heating networks, heating systems in multi-family buildings, industrial facilities and public utilities. By using the MWN130-NC flow transducer, you gain:

Measurement reliability thanks to compliance with MID metrological requirements and the possession of an EC type examination certificate

Capable of operating at a working pressure of up to 16 bar

Resistance to tampering thanks to protection against external magnetic fields

Stable and precise measurement thanks to the application of a double-sided bearing rotor

Easy and clear reading thanks to the clear display

Easy servicing thanks to the removable measuring insert

The ability to check the transducer’s metrological parameters electronically

Can be adapted to the installation thanks to the option of custom flange drilling

Compliance with the MID measuring range: DN40–200:qi/qp = 1:25 – H/V; DN250–300:qi/qp = 1:10 – H/V

Looking for alternatives?
Discover other products in our range

JS90-NC (DN15–20)

Heat meter flow transducers for MID heat meters for the R50-H – EN 1434

Przetworniki przepływu do ciepłomierzy
  • Polish mechanical heat meter flow transducers for JS90–NC

  • Measurement accuracy in accordance with EN 1434, Class 3

  • Resistance to external magnetic fields

See

JS130-NC (DN25–40)

Mechanical vane heat meter flow transducers for MID, R50-H – EN 1434

Ciepłomierz rozłączny JS130-NC
  • Polish mechanical heat meter flow transducers for JS130–NC

  • Measurement accuracy in accordance with EN 1434, Class 3

  • Resistance to external magnetic fields

See

Sharky 473

Sharky 473 – ultrasonic transducers (DN15–100)

Sharky 473 - przetworniki ultradźwiękowe
  • Low starting flow

  • High measurement dynamic range

  • Battery power supply from the heat meter converter

See
cta - zdjęcie po lewej
cta - zdjęcie po prawej

Don’t waste a single drop of water

Find out how our product can help optimise costs and improve the accuracy of your company’s readings