Sharky 473

Sharky 473 – ultrasonic transducers (DN15–100)

  • Low starting flow

  • High measurement dynamic range

  • Battery power supply from the heat meter converter

Ask about this product

Na każdą wiadomość staramy się odpowiadać maksymalnie w 24 godziny (dni robocze).

Find out what the Sharky 473 ultrasonic transducer has to offer

The Sharky 473 is an ultrasonic flow transducer designed for cooperation with split heat meters. The device is used to measure water volume in heating, cooling and mixed hot/cold systems. It operates with water at temperatures ranging from 5°C to 130°C for flow rates of 0.6–2.5 m³/h and up to 150°C for higher flow rates (3.5–60 m³/h), at a maximum operating pressure of 16 bar (PN16). Thanks to ultrasonic technology, the flow meter offers very high measurement stability, low pressure losses and resistance to contamination and limescale build-up. The design allows installation in any position, without the need for straight pipe runs upstream and downstream of the flow meter. The power supply is provided directly from the heat meters, and the absence of moving parts ensures long-term, maintenance-free operation. By using the Sharky 473 ultrasonic transmitter, you gain:

High measurement accuracy and stability thanks to ultrasonic technology

Very low starting flow and low minimum flow rate

Capable of operating at a working pressure of up to 16 bar

High measurement dynamic range thanks to theqi/qp ratio of 1:100, for flow ratesof qp=1.4; 2.5; 6; 10; 15; 25m³/h, withthe qi/qp ratio of 1:250 as an option

Immunity to external magnetic fields

Flexible installation thanks to the ability to install it in any position

Ready for integration with measurement systems thanks to standard pulse outputs (1, 10, 100 l/pulse) and a test output

Looking for alternatives?
Discover other products in our range

JS90-NC (DN15–20)

Heat meter flow transducers for MID heat meters for the R50-H – EN 1434

Przetworniki przepływu do ciepłomierzy
  • Polish mechanical heat meter flow transducers for JS90–NC

  • Measurement accuracy in accordance with EN 1434, Class 3

  • Resistance to external magnetic fields

See

JS130-NC (DN25–40)

Mechanical vane heat meter flow transducers for MID, R50-H – EN 1434

Ciepłomierz rozłączny JS130-NC
  • Polish mechanical heat meter flow transducers for JS130–NC

  • Measurement accuracy in accordance with EN 1434, Class 3

  • Resistance to external magnetic fields

See

MWN130-NC (DN40–300)

Screw transducers (Woltman) with a horizontal rotor axis

Przetwornik śrubowy Woltman MWN130-NC
  • Polish mechanical heat meter flow transducers MWN130-NC

  • Immunity to external magnetic fields, in accordance with EN 14154-3 and EN-ISO 4064-2

  • Accuracy of readings – compliance with MID metrological requirements

See
cta - zdjęcie po lewej
cta - zdjęcie po prawej

Don’t waste a single drop of water

Find out how our product can help optimise costs and improve the accuracy of your company’s readings