Cathodic protection and gas station accessories

Protect your steel infrastructure against corrosion

Discover our range of products for effective cathodic protection and monitoring of gas stations

TELCORR 4

Telemetry module

Telcorr 4
  • Advanced telemetry module for cathodic protection systems

  • Remote control, monitoring and recording of corrosion protection parameters

  • Flexible modular expansion and integration with control and supervison systems

See

MSOK 2

Microprocessor cathodic protection station

MSOK 2 - mikroprocesorowa stacja ochrony katodowej
  • A modern, microprocessor-based station for the electrochemical protection of steel structures

  • A digitally controlled switching power supply with a comprehensive measurement system

  • Advanced telemetry and remote monitoring of operating parameters

See

MSK 2

Microprocessor gas temperature controller

Sterownik kotła MSK 2
  • A comprehensive control system for gas boilers at pressure-reducing stations

  • Advanced control of the gas preheating process

  • Remote monitoring and cascading capability

See

MODCOM W4

Telemetry modem

MODCOM W4 - Modem telemetryczny
  • A reliable modem for data transmission in industrial and process automation systems

  • Reliable GSM (4G/LTE) radio connectivity with SIM card redundancy

  • Support for multiple communication interfaces

See

Take full control of your infrastructure’s corrosion protection

Automate monitoring and reporting, reduce response times to faults and optimise the costs of service call-outs.

New additions to our range

Comprehensive corrosion protection – the CSMOK system

A centralised cathodic protection monitoring system that aggregates data from remote sites, alerts staff to faults and automates reporting.

See product
Zabezpieczenie BELplus OZE
Comprehensive corrosion protection – the CSMOK system MSOK 2 Telemetry module

Reduce infrastructure maintenance costs with reliable cathodic protection

Antykorozja
Our cathodic protection systems adapt their operating mode to the prevailing conditions. The degree of protection IP65 and temperature resistance from −15°C to +70°C ensure durability and reliability, extending the service life of your installation. This will reduce the need for on-site work and minimise maintenance costs.
adobestock_600291090
Optimise your network management by utilising the remote configuration, monitoring and data collection capabilities offered by our solutions. Furthermore, thanks to open communication protocols, you can easily integrate our telemetry module with your master system. This will give you constant access to reliable data to support fault diagnosis and reduce the risk of costly breakdowns.
kobieta
Streamline communication between the operations team and technical services using the Central Cathodic Protection Monitoring System (CSMOK), which provides a comprehensive overview of the infrastructure on a single map. This will help you coordinate tasks and pinpoint incidents instantly. Automatic device configuration and ready-made report templates reduce the time needed to complete these tasks, allowing you to optimise team workflow and streamline reporting.

Frequently Asked Questions

Our devices are based on proven GSM mobile technology (GPRS and LTE).

Yes, they can be queried via a serial connection, which allows for easy connection to various industrial devices.

The battery lifetime ranges from a few months to several years, depending on the schedule you set on the device.

Yes, we offer a full range of services relating to the diagnosis, repairs and calibration of our equipment.

cta - zdjęcie po lewej
cta - zdjęcie po prawej

Ensure comprehensive corrosion protection for your infrastructure

Please contact an advisor who will select the best solutions for your project.

The application of cathodic protection in gas infrastructure

Cathodic protection is one of the most commonly used methods for protecting steel pipelines, valves and tanks against corrosion. It reduces the risk of perforation and leaks by controlling the potential relative to the ground, ensuring a longer service life for the network and minimising the costs of failures.

Corrosion protection in gas systems is generally based on impressed current systems or galvanic anodes. These solutions work in conjunction with insulating coatings and effectively limit the impact of stray currents. Continuous monitoring, remote data reading and protection audits form the basis of modern protection modules, such as TELCORR 4. They enable rapid detection of anomalies, planning of maintenance work, and ensure supply continuity and environmental safety.

The role of high-quality accessories in the safety and durability of gas stations

The reliability of gas stations depends on the quality of accessories, including flange insulators, bushings, earthing systems, cables, exothermic connectors, cathodic protection stations, telemetry modules and drainage stations. The application of high-quality, certified components guarantees stable cathodic protection parameters, resistance to moisture, vibration and salinity, as well as minimising the risk of sparking or leaks. Material compatibility and ease of servicing reduce supply downtime and lower operating costs. This ensures long-term infrastructure protection, greater operational safety and predictable maintenance costs.