Fuse switch disconnectors

Reliable devices designed for energy distribution and circuit protection against the effects of short circuits and overloads, used in industrial LV switchgear, LV switchgear in transformer substations, and cable-distribution joints.

Choose switch disconnectors suited to your installation

ARS 00 evo

Fuse switch disconnector

ARS evo rozłącznik izolacyjny bezpiecznikowy listwowy
  • Tilt-and-turn mechanism

  • A stable and secure electricity distribution network

  • Option to change the direction of the drain flow from top to bottom

See

ARS 2 evo

Fuse switch disconnector

ARS 2 evo rozłącznik izolacyjny bezpiecznikowy listwowy
  • Tilt-and-turn mechanism

  • A stable and secure electricity distribution network

  • Option to change the direction of the drain flow from top to bottom

See

ARS 3 evo

Functional fuse switch disconnector

ARS 3 evo rozłącznik izolacyjny bezpiecznikowy listwowy
  • Tilt-and-turn mechanism

  • A stable and secure electricity distribution network

  • Option to change the direction of the drain flow from top to bottom

See

smartARS 00 Pro

Fuse switch disconnector

Rozłącznik izolacyjny smartARS 00 pro
  • Suitable for NH00-size fuses (160 A)

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See

smartARS 2 Pro

Fuse switch disconnector

Rozłącznik izolacyjny smartARS 2 pro
  • Suitable for fuses of size NH1 (250 A) and NH2 (400 A)

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See

smartARS 3 Pro

Fuse switch disconnector

Rozłącznik izolacyjny smartARS 3 pro
  • Suitable for NH3-size cartridges (630 A)

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See

smartARS-X Pro

Vertical fuse switch disconnector with fuse monitoring module

Rozłącznik izolacyjny smartARS X pro
  • SMW fuse link burnout module

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See

smartARS-XT pro

Vertical fuse switch disconnector with fuse monitoring module

Rozłącznik izolacyjny smartARS-XT pro
  • SMR fuse link blowout module

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See

smartARS pro-PV

Fuse switch disconnector

smartARS pro-PV – rozłącznik bezpiecznikowy listwowy
  • They protect circuits with new-generation 800 V AC inverters

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Quick installation using PPN technology

See

smartARS P pro

Vertical fuse switch disconnector with current transformers

Rozłącznik izolacyjny smartARS P pro
  • Switch disconnectors with current transformers built into the base

  • The transformers built into the base of the unit do not increase its overall dimensions (saving space in the switchgears or cabinet)

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

See

smartARS 00 pro IP20

Vertical fuse switch disconnector with a hook adapter for IP20 busbar installation

Rozłącznik izolacyjny smartARS 00 pro IP20
  • Suitable for NH00-size fuses (160 A)

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See

smartARS 2 pro IP20

Vertical fuse switch disconnectors with a hook adapter for IP20 busbar

Rozłącznik izolacyjny smartARS 2 pro IP20
  • Suitable for fuses of size NH1 (250 A) and NH2 (400 A)

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See

smartARS 3 pro IP20

Vertical fuse switch disconnectors with a hook adapter for IP20 busbar, IP20

Rozłącznik izolacyjny smartARS 3 pro IP20
  • Suitable for NH3 (630) size inserts

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See

ARS 00/60 mm Pro

Fuse switch disconnector

Rozłącznik izolacyjny ARS 00/60 mm pro
  • Suitable for NH00-size fuses (160 A)

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See

ARS 00/100 mm Pro

Fuse switch disconnector

Rozłącznik izolacyjny - ARS 00/100 mm pro
  • Suitable for NH00-size fuses (160 A)

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See

ARS 630 kVA Pro

Fuse switch disconnector

Rozłącznik izolacyjny ARS 630 kVA pro
  • Main switch disconnector for transformers with a capacity of up to 630 kVA

  • Suitable for NH3-size (630 A) fuses with a gTr rating

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

See

ARS 1250 Pro

Fuse switch disconnector

Rozłącznik izolacyjny ARS 1250 pro
  • Suitable for NH3-size cartridges (630 A)

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See

ARS NL No. pro

Vertical fuse switch disconnector with lateral busbar terminals

Rozłącznik izolacyjny ARS NL NR  pro
  • A switch disconnector for disconnecting and connecting busbar systems

  • Suitable for inserts of size NH2 (400 A) and NH3 (630 A)

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

See

RWS 600 Pro

Fuse switch disconnectors

Rozłącznik izolacyjny RWS 600 pro
  • Designed for the installation of size 2 knife clamps

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See

RWS 750 Pro

Fuse switch disconnectors

Rozłącznik izolacyjny RWS 750 pro
  • Designed for fitting size 3 knife clamps

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See

RWS 1250 Pro

Fuse switch disconnectors

Rozłącznik izolacyjny RWS 1250 pro
  • Suitable for installing knife switches of sizes 3 to 1250 A

  • A flame-retardant, self-extinguishing plastic with a V0 flammability rating

  • Two-pole contact arrangement

See
cta - zdjęcie po lewej
cta - zdjęcie po prawej

Make sure your electrical installation is safe

Choose switch disconnectors that protect your network from overloads

What should you look out for when choosing isolating switches?

Switch disconnectors play a key role in every electrical installation, protecting it from the effects of short circuits and overloads. Therefore, the purchasing decision requires not only analyses of technical parameters (e.g. rated current, mechanical endurance, IP rating), but also an assessment of other factors that affect the safety of the installation and personnel. Here are a few of them:

  • features – find out whether the switch disconnectors can lock the drive in a specific position and whether they offer the option to change the up/down direction of movement. Check whether they allow for contactless replacement of fuse links and remote monitoring;
  • safety – verify standards compliance with Polish and European standards, confirmed by certificates. Check the design for optimal heat dissipation, flammability class and level of protection against direct contact;
  • installation flexibility – assess the speed and ease of installing the switch disconnectors for staff. Check which mounting systems the device is compatible with (e.g. busbars, mounting plates, DIN TH-35 rails);
  • infrastructure compatibility – enquire about related solutions, e.g. switchgear monitoring software, busbar systems or product standardisation within a single solution group.

If you are unsure whether a particular switch disconnector is the right choice for your installation, please contact us. We will help you make a decision and support you through the subsequent stages of implementation.