Drive accessories

Optional accessories are components that are not always required when installing our drive systems, but which often make the solutions more durable, ensure they meet higher standards, or simply make the equipment easier to operate. Such components include EMC filters, chokes, braking resistors, setpoint potentiometers, ready-made setpoint controllers, tachogenerators and many other items.

Choose additional accessories to help you build a well-functioning app

Braking resistors

resistor
  • For DBR-type frequency converters

  • For BR-type inverters

  • Degree of protection IP00

See

Sine-wave filters

dlawik-sinusoidalny
  • Easy installation

  • The ideal intermediary component between the inverter and the motor

  • Shaping the sinusoidal waveform of the output current

See

Motor chokes

dlawik-silnikowy
  • Reduction in the steepness of the du/du voltage response

  • Capacitive compensation for long cable runs

  • Low noise level

See

Line reactors

dlawik-sieciowy-3-fazowy
  • Single-phase line reactors – on the power supply side of the converter

  • 3-phase line reactors – on the converter’s power supply side

  • Reducing the steepness of the current rise during commutation

See

PATO tachogenerator

tachopradnica pato
  • DC tachogenerator

  • Through-shaft output shaft available in 4 different diameters

  • Permanent magnets under excitation

See

PZTK tachogenerator

tachopradnica pztk
  • DC tachogenerator with an output shaft

  • Permanent magnets under excitation

  • Both analogue and digital solutions offered by Apator Control

See

Protect your system

Choose tried-and-tested drive accessories and technologies that enhance the reliability and safety of the drive system

New additions to our range

REMIZ 1

Direct-connected DIN rail electricity meter

See product
Remiz 1

REMIZ 3B

Direct-connected DIN rail electricity meter

See product
Remiz 3B
REMIZ 1 REMIZ 3B REMIZ 3P REMIZ 3PP
Obraz
magazyn energii 5
Obraz
robot3
Obraz
Właściwa eksploatacja i cyfrowe zarządzanie farmami
Obraz
Panele fotowoltaiczne
Obraz
Słupy energetyczne
Obraz
Magazyn Apator Enea 1
Obraz
Magazyn Tauron
Obraz
Klaster Słupski

Find out how we support our customers

Take a look at our projects and find out more about solutions that improve comfort and safety when working on electrical installations.

See all projects

The Apator Group with an innovative IT solution for the Słupsk Cluster

Find out more about systems that give you full control over processes, enabling you to ensure the optimal use of local energy from RES.

Energy storage in the low voltage grid for TAURON Dystrybucja

Find out how energy storage helps stabilise the operation of the low voltage distribution network.

Enea Operator launches a new energy storage facility in the low voltage grid

Find out more about connecting an industrial energy storage facility to the low voltage grid in Bydgoszcz.

Pilot project to build a smart grid

Find out how a smart power grid with remote control and automation for protection systems is created

The fotovoltaic farm in Susz featuring the EKTIN PV system

The EKTIN PV system for the control and monitoring of photovoltaic farms has been implemented at two photovoltaic farms in Susz

Operation and digital management of fotovoltaic farms

Find out more about how EKTIN software is used to monitor fotovoltaic farms

Robotization and automation in the Apator Group’s production facilities

Find out more about how we automate our production facilities.

Energy storage for stabilising the low-voltage electricity grid

A pilot energy storage project carried out for Tauron Dystrybucja.

Expert insights

Find out how correctly selected switch disconnectors improve safety, make maintenance work easier and protect your installation against unforeseen incidents.

cta - zdjęcie po lewej
cta - zdjęcie po prawej

Choose the best solutions

Find out which accessories and solutions are best suited to your installation

What should you look out for when choosing isolating switches?

Switch disconnectors play a key role in every electrical installation, protecting it from the effects of short circuits and overloads. Therefore, the purchasing decision requires not only analyses of technical parameters (e.g. rated current, mechanical endurance, IP rating), but also an assessment of other factors that affect the safety of the installation and personnel. Here are a few of them:

  • features – find out whether the switch disconnectors can lock the drive in a specific position and whether they offer the option to change the up/down direction of movement. Check whether they allow for contactless replacement of fuse links and remote monitoring;
  • safety – verify standards compliance with Polish and European standards, confirmed by certificates. Check the design for optimal heat dissipation, flammability class and level of protection against direct contact;
  • installation flexibility – assess the speed and ease of installing the switch disconnectors for staff. Check which mounting systems the device is compatible with (e.g. busbars, mounting plates, DIN TH-35 rails);
  • infrastructure compatibility – enquire about related solutions, e.g. switchgear monitoring software, busbar systems or product standardisation within a single solution group.

If you are unsure whether a particular switch disconnector is the right choice for your installation, please contact us. We will help you make a decision and support you through the subsequent stages of implementation.